How to assess a cobot welding robot maker's safety integration

How to assess a cobot welding robot maker's safety integration

Nov 05, 2026

A collaborative robot arm is not, by itself, evidence that a welding cell is safe for people to work beside. The torch, electric arc, hot workpiece, positioning equipment and welding fumes introduce hazards that the arm’s collision-detection functions do not necessarily control. The decisive question is whether the supplier can demonstrate that safeguards work together for the intended task, layout and operating modes.

When assessing a cobot welding robot manufacturer, look beyond a list of protective features. Ask for a task-specific risk assessment, a defined safety architecture and a plan to validate the installed cell. A credible proposal should also explain which responsibilities remain with the integrator and the user, especially where extraction, guarding or positioners come from different suppliers.

Start with the complete cell, not the robot specification

A robot may be described as collaborative because it can support particular collaborative operating methods. That description does not establish that every movement, tool or welding operation is suitable for unrestricted human access. A welding torch can present sharp edges and burn hazards; a positioner can create trapping points; and an arc can expose nearby people to optical radiation even when the robot is moving slowly.

Ask the supplier to define the proposed cell boundaries on a layout drawing. The drawing should include the robot’s working envelope, fixtures, positioners, loading areas, screens, extraction equipment, operator positions and access routes. It should also show where people may be during welding, loading, teaching, cleaning and maintenance.

The distinction matters when equipment is compared across automation categories. For example, a Space frame welding machine designed for truss structures can weld both sides of a workpiece and uses hydraulically operated support devices. Those characteristics create different access and movement risks from a single-arm cobot cell; they should not be interpreted as evidence of collaborative operation. The same assessment principle applies: evaluate the entire machine and its intended tasks, not the automation label.

Examine the risk assessment for real operating tasks

Request a risk assessment that identifies hazards, exposed persons, foreseeable misuse, existing safeguards and residual risks. It should be specific enough to connect each significant hazard to the cell layout and operating sequence. A generic robot risk assessment that stops at the arm’s mounting flange leaves too much unanswered.

Pay particular attention to situations in which normal production safeguards are suspended, bypassed or less effective:

  • Loading and unloading: Can a person reach a moving fixture or hot part? What prevents a cycle from starting while hands are inside the hazardous area?
  • Teaching and touch-up: What movements are permitted, at what speed, and under whose control? Does the operator need to be close to the torch or fixture?
  • Torch cleaning and wire changes: How are unexpected robot movement, welding output and wire-feed movement controlled?
  • Clearing faults: What happens if a part is misaligned, a weld is interrupted or a positioner stops between positions?
  • Maintenance: Which electrical, pneumatic, hydraulic or gravity-related energy sources require isolation or mechanical restraint?

For each task, ask why the selected protective measure is appropriate. For example, a scanner-triggered stop may control access during automatic operation, while maintenance inside the cell may require energy isolation rather than reliance on a protective stop. The assessment should make that distinction explicit.

A useful test is traceability: choose one hazard, such as a hand trapped between the fixture and positioner, and follow it through the risk assessment, layout, safety requirements and validation record. If the supplier cannot show how the risk is reduced and checked, the integration is not yet adequately demonstrated.

Check how stops and safety functions interact

Emergency stops, protective stops and controlled operating modes serve different purposes. An emergency stop is a complementary emergency measure, not a substitute for guarding or a routine method of entering the cell. A protective stop triggered by an interlocked gate or safety scanner must be designed around the hazardous movement and the time required to stop it.

Request a safety-function specification or equivalent documentation covering the initiating device, logic, final outputs, intended response and reset conditions. It should identify the equipment affected: robot axes, positioner, torch movement, welding output and other relevant devices. A stop that halts the robot but leaves a rotating fixture active may not address the reason access was restricted.

For safety-related control functions, ask how the required performance level or safety integrity level was determined and achieved. Depending on the design and applicable framework, this may involve standards such as ISO 13849-1 or IEC 62061. A component certificate alone does not establish the performance of the complete function: wiring, logic, outputs, fault behavior and validation all matter.

Questions worth resolving before approval include:

  • Does opening an access gate stop all hazardous motion associated with that access point?
  • Where a scanner is used, are its protective fields based on stopping performance, approach and reach, and the actual cell geometry?
  • Can the cell restart automatically after a person leaves the protected area, or is a deliberate reset and separate start required by the chosen design?
  • Is the reset location positioned so the hazardous area can be checked without exposing the person resetting it?
  • What happens after a power interruption, communication fault or safety-device failure?

Stopping distance and time should be measured or otherwise substantiated for the installed configuration, including the relevant load, speed and positioning equipment. Scanner placement based only on the robot catalogue can be misleading if the fixture or workpiece changes the time or distance needed to reach a safe state.

Scrutinize the proposed collaborative mode

Terms such as “force limited,” “hand guided” and “speed monitored” describe different approaches; they are not interchangeable assurances. Ask which mode is intended for each task and whether people are expected to share space with the robot during movement, during welding, or only between cycles.

Where power-and-force limiting is proposed, the assessment must consider the complete contact situation: robot, torch, workpiece, fixture, body region and possible clamping against surrounding structures. A sharp torch tip or hot component can make an otherwise acceptable contact strategy unsuitable. Force limits are not a substitute for controlling arc exposure or fumes.

Where speed and separation monitoring is proposed, the supplier should explain how people are detected, how protective distances are established and what happens if the detection field is obstructed. Welding screens, fixtures and workpieces can affect sensor coverage. A layout that looks clear on a drawing should be checked with the actual production equipment in place.

For hand guiding or teaching, examine the enabling device, speed limits, operator position and transition back to automatic operation. The key question is not whether the controller offers a mode, but whether that mode can be used safely for the intended task without encouraging improvised bypasses.

Assess welding hazards outside the robot controller

Fume extraction. Ask the supplier to identify expected fume sources, the proposed capture arrangement and who is responsible for sizing, installation and commissioning. Capture performance depends on process, material, consumables, torch orientation, airflow and the position of the extraction inlet. A movable or robot-mounted inlet must remain effective throughout the weld path without colliding with the part or disrupting shielding gas.

Request provisions for checking airflow or system condition and maintaining filters and ductwork. A functional extraction fan is not proof that exposure is controlled at the operator’s breathing zone; workplace exposure assessment may still be necessary under local requirements.

Arc radiation and spatter. Welding curtains or screens should address sightlines from loading stations, walkways and neighboring work areas, including reflected radiation where relevant. Examine openings needed for part handling and extraction: a screen that protects the front of the cell may leave an exposed side. Screens and barriers also need to be suitable for the welding environment and maintained when damaged.

Electrical, fire and thermal hazards. Review cable routing, grounding arrangements, protection against damaged insulation, shielding-gas cylinders and nearby combustible materials. Define how hot parts are identified and handled after the arc stops. If the process uses flammable materials or creates a particular fire risk, the site’s fire protection arrangements must be considered alongside the equipment design.

Connect safety integration to weld quality

Safeguards can influence process stability. Excessive extraction airflow near the arc can disturb shielding gas, while a poorly positioned capture hood can obstruct the torch or prevent access to a joint. Conversely, removing or repositioning extraction to reach a difficult weld can undermine exposure control.

Ask the supplier to demonstrate representative welds with the intended fixtures, extraction, screens and operating sequence in place. Review the consequences of protective stops during a weld: how is an interrupted weld identified, repaired or rejected, and how are restart locations controlled? A cell that restarts conveniently but leaves an unrecorded incomplete weld creates a quality problem as well as a control problem.

Changes to part geometry, fixture positions, consumables or welding parameters can affect both quality and safety. The handover procedure should identify which changes the user can make within defined limits and which require a fresh risk assessment or supplier review.

Use standards and documentation as evidence, not slogans

Ask which standards and legal requirements the supplier has applied to the robot system, machinery, electrical equipment and welding process in the destination market. ISO 10218-1 and ISO 10218-2 address industrial robot safety and robot applications or cells respectively; ISO/TS 15066 provides additional guidance relevant to collaborative industrial robot operation. Applicable editions and the relationship between standards and legal obligations depend on jurisdiction and the date of supply.

For machinery supplied into the European Economic Area, ask who is responsible for the conformity assessment of the complete assembly and what declaration and technical documentation will be provided under the applicable legislation. A CE mark on the robot arm, power source or another component does not by itself establish conformity of the assembled cell. ISO 9001 certification likewise concerns a quality management system; it is not proof that a particular welding installation is safe.

The delivery package should include the risk assessment or agreed relevant extracts, operating and maintenance instructions, electrical and pneumatic diagrams as applicable, safety-function details, residual risks and validation records. Where information is split among vendors, assign an owner for the integrated documentation rather than accepting disconnected manuals.

Make acceptance depend on the installed cell

Factory acceptance can establish that the proposed control logic and equipment operate as intended, but site acceptance must account for the actual layout, utilities, extraction, workpieces and surrounding traffic. Agree on acceptance criteria before ordering, including who supplies test parts and who records and closes defects.

Witness tests should cover normal cycles and foreseeable faults: opening each interlocked access point, entering scanner zones from relevant directions, pressing each emergency stop, interrupting power and testing reset and restart behavior. Observe both robot and positioner responses. Verify extraction and shielding arrangements during representative welding rather than only with the arc off.

Training should cover routine operation, safe loading, mode selection, fault response, isolation and the limits on changing programs or fixtures. Request a handover of outstanding issues with owners and closure dates. If a critical protective function cannot be validated, production acceptance should wait until it is corrected and retested.

search

Send Us A Message

Submit